M A T E R I A L S A F E T Y D A T A S H E E T  
For Welding Consumables and Related Products  
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988  
SECTION I - IDENTIFICATION  
Manufacturer/  
Supplier:  
The Lincoln Electric Company  
22801 St. Clair Avenue  
Cleveland, OH 44117-1199  
(216) 481-8100  
Carbon Steel Electrode  
AWS ER70S-6  
Product Type:  
Classification:  
SECTION II - HAZARDOUS MATERIAL (1)  
I M P O R T A N T !  
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal  
use of this product are covered by Section V; see it for industrial hygiene information.  
CAS Number shown is representative for the ingredients listed.  
(1) The term “hazardous” in “Hazardous Materials” should be interpreted as a term required and defined in the Hazards Communication  
Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.  
TLV  
PEL  
Ingredients:  
CAS No.  
Wt.%  
mg/m3  
mg/m3  
Carbon steel wire  
100  
10*  
10*  
Nominal wire composition:  
Total manganese *****  
7439-96-5  
7440-50-8  
7439-89-6  
< 2.0  
< 0.5  
bal.  
0.2  
0.2(a)  
10*  
1.0(c)  
0.1(a)  
10*  
Total copper including plated coating *****  
Iron  
Supplemental Information: (*) Not listed. Nuisance value maximum (c)  
is 10 milligrams per cubic meter. PEL value for iron oxide is 10 milligrams per  
cubic meter. TLV value for iron oxide is 5 milligrams per cubic meter.  
Values are for manganese fume. STEL (Short  
Term Exposure Limit) is 3.0 milligrams per cubic  
meter. Values are those proposed by OSHA in  
1989. Present PEL is 5.0 milligrams per cubic  
meter (ceiling value).  
(*****) Subject to the reporting requirements of Sections 311, 312, and 313 of  
the Emergency Planning and Community Right-to-Know Act of 1986  
and of 40CFR 370 and 372.  
(a)  
Values are for copper fume.  
SECTION III - HAZARD DATA  
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI.  
Product is inert, no special handling or spill procedures required. Not regulated by DOT.  
Rev 11/06  
(CONTINUED ON SIDE TWO)  
 

Westinghouse Computer Monitor LCM 20v5 User Manual
Whirlpool Air Conditioner 3PACH21DD0 User Manual
Whirlpool Freezer ETZOZK User Manual
Winegard TV Antenna CC 7870 User Manual
Yamaha CD Player CRW8824E User Manual
Yamaha Stereo Receiver HTR 5830 User Manual
Zanussi Freezer VF45 User Manual
Zanussi Freezer ZBF 6114 User Manual
Zanussi Range ZDF 290 User Manual
Zanussi Refrigerator HB2P4CR User Manual