Electrical: A 120-Volt, 60-Hz, AC-only, 15- or 20-amp fused electrical  
supply with a fuse or circuit breaker. A time-delay fuse or time-delay circuit  
breaker is recommended. It is recommended that a separate circuit serving  
only this microwave oven be provided.  
VENTING REQUIREMENTS  
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.  
CABINET OPENING DIMENSIONS  
The total length of the vent system including straight vent, elbow(s), transitions and wall  
or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent.  
For best performance, use no more than three 90° elbows.  
The grounded 3-prong outlet must be inside the upper cabinet.  
A
B
To calculate the length of the system you need, add the equivalent length for each vent  
piece used in the system. See the following examples:  
A
B
C
30"  
(76.2 cm)  
min.  
30" (76.2 cm) typical*  
12" (30.5 cm) min.  
14" (35.6 cm) max.  
66" (167.6 cm) min.  
D
E
F
G
A. Rectangular to round transition piece: 3 " x 10" to 6" = 5 ft  
(8.3 x 25.4 cm to 15.2 cm = 1.5 m)  
B. Roof cap: 3 " x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)  
C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)  
D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)  
E. Wall cap: 3 " x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)  
F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)  
G. 90° flat elbow: 3 " x 10" = 10 ft (8.3 x 25.4 cm = 3 m)  
6" (15.2 cm) vent system = 73 ft (22.2 m) total  
A
B
6 ft (1.8 m)  
A. 2" x 4" wall stud  
B. Grounded 3-prong outlet  
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.  
Exact dimensions may vary depending on type of range/cooktop  
below.  
2 ft  
(0.6 m)  
A. Two 90° elbows = 20 ft (6.1 m)  
B. 1 wall cap = 40 ft (12.2 m)  
C. 1 rectangular to round transition  
piece = 5 ft (1.5 m)  
D. 2 ft (0.6 m) + 6 ft (1.8 m)  
straight = 8 ft (2.4 m)  
Rectangular to Round Transition for Roof Venting  
NOTE: The minimum 3" (7.6 cm) clearance must exist between  
the top of the microwave oven and the rectangular to round  
transition piece so that the damper can open freely and fully.  
C
D
3 " x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total  
A
B
A
6 ft (1.8 m)  
B
2 ft  
(0.6 m)  
D
C
A. Roof cap  
B. 6" (15.2 cm) min. diameter round vent  
C. Elbow (for wall venting only)  
D. Wall cap  
E. 3 " x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)  
rectangular to round transition piece  
C
E
F
A. One 3 " x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)  
B. 1 wall cap = 40 ft (12.2 m)  
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)  
3" (7.6 cm)  
F. Vent extension piece, at least 3" (7.6 cm) high  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10238252A  
5/09  
 

Western Telematic Switch CAS 161A User Manual
Whirlpool Cooktop W10458809B User Manual
Whirlpool Freezer EV11OCX User Manual
Windmere Kitchen Utensil EK1 User Manual
Windsor Vacuum Cleaner 22 User Manual
Winegard Satellite TV System RP SK95 User Manual
Wolfgang Puck Electric Pressure Cooker BPCR0010 User Manual
Xerox All in One Printer 5632 User Manual
Zebra Technologies Network Router 13743L 004 User Manual
Zenoah Chainsaw G4200EZ User Manual