Planning Information
Models DD45I and DD45R Downdraft Systems
9" (229) chimney
elevation
Top cover
Model DD45I
Internal Blower
Three-speed blower
control
Model DD45R
In-Line or
Remote Blower
Remote-mounted
control module
Aluminum mesh
filters
Stainless steel filter
covers
Location of rating
plate
The cooktop downdraft unit rises from the countertop
to whisk away odors and smoke into the easy-to-clean,
five-layer mesh filter. The control module and top cover
come in classic stainless steel only and are included
with the downdraft.
Model DD45I 45" (1143) downdraft
ventilation system includes a 500 CFM
internal blower. In-line and remote blower
options are available for Model DD45R.
Control module and top cover come in
classic stainless steel only and are
included with the downdraft.
Wolf downdraft ventilation systems are recommended
for use with Wolf electric and gas cooktops and
integrated modules, excluding the unframed electric
cooktops and electric grill, steamer and fryer modules.
Wolf downdraft systems cannot be used with Wolf dual
fuel ranges, gas ranges, sealed burner rangetops and
gas rangetops.
Dimensions in parentheses are in
millimeters unless otherwise specified.
1
9/06
Planning Information
Models DD45I and DD45R Downdraft Systems
M O D E L O P T I O N S
S P E C I F I C A T I O N S
Overall Width
Downdraft with 500 CFM
Internal Blower Included
451/2" (1156)
91/16" (230)
DD45I
Overall Height (above countertop)
Overall Depth
Downdraft Only — In-Line or
Remote Blower Required
23/8" (60)
DD45R
Duct Size (Model DD45I)
Duct Size (Model DD45R)
Discharge
31/4" (83) x 10" (254)
31/4" (83) x 14" (356)
Adjustable
Control module, top cover, mounting
brackets, DIN connector and mounting
hardware included with the downdraft.
For Model DD45R see in-line and remote
blower options below.
Electrical Supply Requirements
110/120 V AC, 60 Hz
15 amp dedicated circuit
Power Cord
21/2' (.8 m) power cord with
3-prong grounded plug
B L O W E R O P T I O N S
1100 CFM In-Line Blower
900 CFM Remote Blower
1200 CFM Remote Blower
1500 CFM Remote Blower
808332
801641
801642
804701
Shipping Weight
85 lbs (39 kg)
Specifications are subject to change without notice.
Refer to the Wolf Cooktop Ventilation
Recommendations chart at the end of this
section.
A C C E S S O R I E S
Transitions in various sizes
Accessories are available through your
Wolf dealer. To obtain local dealer
information, visit the Locator section of
our website, wolfappliance.com.
C O U N T E R T O P C U T- O U T
3
2 /4" (70)
42" (1067)
1
25 /8" MIN
(638)
1
FLAT
COUNTERTOP
SPACE
19 /4"
COOKTOP CUT-OUT
WIDTH
(489)
1
2 /2" MIN
(64)
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Planning Information
Models DD45I and DD45R Downdraft Systems
1
25 /8" MIN (638)
3
1 /4" MIN (45)
BACK EDGE
OF FLAT COUNTERTOP*
OF COOKTOP
TO INSIDE OF
CABINET BACK*
5
/8"
1
2 /2" MIN
(16)
1
(64)
19 /4" (489)
WITH NO
RAISED LIP*
COOKTOP CUT-OUT
DEPTH
.344"
3
2 /8" (60)
11
7
/16"
1
2 /8" (54)
(197)
1
3 /4"
(83)
5
29 /16"
(745)
COUNTERTOP
TO BOTTOM OF
AIR BOX
5
3 /8"
(92)
36"
(914)
18"
5"
(457)
(127)
1
7 /8"
(181)
24" MIN (610)
CABINET DEPTH
*AREAS OF POTENTIAL INTERFERENCE
L O C A T I O N O F E L E C T R I C A L
4"min (102)
1
3 /2" (89)
E
E
24"min (610)
CABINET DEPTH
10" (254)
ELECTRICAL LOCATION
IN CABINET BACK
OPTIONAL
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET
1
45 /2"min (1156)
D I M E N S I O N S
Downdraft Cut-Out Width
Minimum Cabinet Width
Downdraft Cut-Out Depth
Location of Electrical
42" (1067)
451/2" (1156)
23/4" (70)
Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
Planning Information
Models DD45I and DD45R Downdraft Systems
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
Wolf downdraft ventilation systems require a
for overall dimensions and installation specifics.
separate, grounded 120 V AC, 60 Hz power
supply. The service should have its own 15
amp circuit breaker and a grounded 3-prong
receptacle should be located within the reach of
the 2' (.6 m) power cord. The specific location
of the outlet is not critical, as long as it is
within reach of the power cord that is located
mid-way, top and bottom on the right side of
the downdraft.
Wolf downdraft ventilation systems are
recommended for use with Wolf electric and
gas cooktops and integrated modules, excluding
the grill, steamer and fryer modules. The down-
draft should be at least as wide as the cooking
surface.
IMPORTANT NOTE: Wolf downdraft ventilation
systems cannot be used with Wolf dual fuel
ranges, gas ranges, sealed burner rangetops
and gas rangetops. A Wolf Pro ventilation hood
should be used.
If the 45" (1143) downdraft is being installed
in a 45" (1143) wide cabinet, the outlet cannot
be located on the back wall of the cabinet. It is
recommended that the outlet be placed in an
adjacent cabinet within reach of the power
cord. Refer to the Location of Electrical illustra-
tion on page 4.
The 45" (1143) downdraft will fit most 45"
(1143) wide cabinets. Cabinet backs may need
to be removed. It is recommended that over-
sized cabinets be used for easier installation.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
To incorporate a downdraft system and a
Wolf cooktop, you must allow for a minimum
251/8" (638) flat counter space from front to
back. A countertop with a raised lip and/or
backsplash may not allow enough space for
proper installation. 23/8" (60) of flat countertop
is required behind the cooktop and 13/4" (44) is
necessary between the back edge of the
cooktop and inside of cabinet back. Follow
dimensions given in the Countertop Cut-out
illustration on page 3.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
This appliance must be used with a Wolf
approved remote mounted control module and
top cover, which is included with the down-
draft.
Installation of the control module must be
within 10' (3 m) of the downdraft assembly and
a minimum of 4" (102) from the outer edge of
cooktop element or burner. You will be required
to drill three holes and connect the two units
by the provided wire.
Model DD45I has a 500 CFM internal blower.
Model DD45R is shipped without the blower
assembly. In-line and remote blower assemblies
are available. Blower options vary with the
volume of air that needs to be moved and the
length of the duct run. Refer to the charts at the
end of this section for cooktop ventilation
recommendations and blower options.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.
IMPORTANT NOTE: Install this downdraft only
with a Wolf blower.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Planning Information
Models DD45I and DD45R Downdraft Systems
D U C T I N G C O N S I D E R A T I O N S
Except for Models DD30I, DD36I and DD45I,
which include a 500 CFM internal blower, Wolf
downdrafts are shipped without the blower
assembly. In-line and remote blower assemblies
are available through your Wolf dealer. To obtain
local dealer information, visit the Locator section
of our website, wolfappliance.com.
Wolf downdraft systems have an adjustable
discharge that will allow you to negotiate
ducting around floor joists and other obstacles.
Three different discharge locations are available
with side to side adjustment for accurate align-
ment of ductwork. Refer to the illustration below
for discharge location options.
IMPORTANT NOTE: Install this downdraft
ventilation system only with a Wolf blower.
Discharge location
options for internal and
remote blower models.
3
CENTERLINE OF COUNTERTOP CUTOUT
16 /8" (416)
INTERNAL BLOWER
1
21 /2" (546)
REMOTE BLOWER
C
L
RIGHT
DISCHARGE
LOCATION
1
22 /8" (562)
INTERNAL BLOWER
19" (483)
REMOTE BLOWER
1
5 /2" (140)
INTERNAL BLOWER
1
4 /4" (108)
REMOTE BLOWER
LEFT
DISCHARGE
LOCATION
DISCHARGE CUTOUT
DIMENSIONS:
1
1
10 /4" (260) x 3 /2" (89)
INTERNAL BLOWER
1
1
14 /4" (362) x 3 /2" (89)
REMOTE BLOWER
CENTERLINE OF COUNTERTOP CUTOUT
C
L
ADJUSTMENT:
1" (25) - 7" (178)
INTERNAL BLOWER
1
2 /2" MAX (165)
REMOTE BLOWER
ADJUSTMENT:
1
5 /2" (140)
5" MAX (127)
REMOTE BLOWER
INTERNAL BLOWER
1
4 /4" (108)
BOTTOM
DISCHARGE
LOCATION
REMOTE BLOWER
NOTE: Measurements are to centerline of duct cutouts
Dimensions in parentheses are in
millimeters unless otherwise specified.
6
Planning Information
Models DD45I and DD45R Downdraft Systems
D U C T I N G C O N S I D E R A T I O N S
For best performance, 10" (254) round ductwork
is recommended. The downdraft will operate
most efficiently when ductwork does not exceed
40' (12 m) in length. Consult a qualified HVAC
engineer for specific ducting applications.
Choose the ducting option that allows the
shortest length of ductwork and a minimum
number of elbows and transitions. Refer to the
illustration below for ducting options.
Refer to the cooktop ventilation charts at the end
of this section for recommendations and blower
options.
IMPORTANT NOTE: All Wolf downdrafts must
be vented to the outside. Use only metal
ductwork.
Ducting options for
downdraft Models DD45I
and DD45R.
10"
ROUND
REMOTE
BLOWER
WALL CAP
12" MIN
TO
GROUND
INTERNAL BLOWER
REMOTE BLOWER
INSTALLATION THROUGH WALL
ROOF MOUNT INSTALLATION
REMOTE
BLOWER
10"
ROUND
12" MIN
TO
GROUND
12" MIN
TO
GROUND
INTERNAL BLOWER
REMOTE BLOWER
INSTALLATION THROUGH WALL
INSTALLATION THROUGH WALL
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Planning Information
Wolf Ventilation Recommendations
W O L F B L O W E R A S S E M B L I E S
A ventilation system must include a blower
assembly. With a few exceptions where internal
blowers are included, Wolf ventilation hoods and
downdrafts are shipped without the blower
assembly. An internal, in-line or remote blower
assembly must be selected to accommodate the
cooking appliance, CFM requirements and home-
owner preferences. Internal, in-line and remote
blower assemblies are available as sales acces-
sories through your Wolf dealer.
IMPORTANT NOTE: Use only a Wolf blower
with all Wolf ventilation products.
Internal blowers are mounted inside the hood
canopy or downdraft blower box. In-line blowers
are mounted in between the hood and the
exterior of the home. Remote blowers can be
mounted on the roof or in some cases, on an
exterior wall. Refer to the illustrations below for
dimensions of Wolf in-line and remote blowers.
Ventilation recommendation charts on the
Wolf internal, in-line and remote blowers are for
use with Wolf cooktop hoods, downdraft
systems and Pro ventilation hoods and hood
liners.
following pages provide minimum CFM recom-
mendations according to the cooking appliance
and ventilation system used and blower options
for each specific ventilation hood or downdraft.
7
24 /8"
3
24 /8"
(632)
(619)
3
11 /4"
(298)
18"
12"
(457)
1
(305)
18 /2"
(470)
1
4 /2"
(114)
8"
(203)
1
21 /2"
1
(546)
22"
12 /4"
(311)
18"
(559)
(457)
In-line BLOWER-60IL
In-line BLOWER-110IL
18" (457)
21" (533)
3
20 /4"
10"
10"
(527)
(254)
(254)
1
1
28 /4"
29 /2"
1
29 /2"
(749)
(718)
(749)
10" (254)
Diameter
10" (254)
Diameter
10" (254)
Diameter
1
3
15 /2"
(394)
3
14 /4"
(375)
14 /4"
(375)
1
1
29 /2"
1
29 /2"
24 /2"
(749)
(749)
(622)
1
3
14"
10 /8"
10 /8"
(356)
(257)
(264)
3
4
/4"
3
(121)
24 /4"
(629)
1
7
1
7
22"
25"
/4"
/4"
(559)
(635)
(184)
(184)
Remote BLOWER-60REM and
BLOWER-90REM
Remote BLOWER-120REM
Remote BLOWER-150REM
Dimensions may vary by 1/8" (3).
Dimensions in parentheses are in
millimeters unless otherwise specified.
8
Planning Information
Wolf Cooktop Ventilation Recommendations
C O O K T O P V E N T I L A T I O N C F M R E C O M M E N D A T I O N S
Cooktop Hoods, Downdrafts and Pro Hoods
CTWH30
CTWH36
IH4227
DD30
DD36
DD45
Pro Hoods
Electric Cooktops
Model CT15E
Model CT30E
Model CT30EU
Model CT36E
Model CT36EU
215*
450
450
215*
600
600
600
600
215*
600
600
600
600
215*
500
150*
350
215*
600
600
600
600
500
CTWH30
CTWH36
IH4227
DD30
DD36
DD45
Pro Hoods
Gas Cooktops
Model CT15G
Model CT30G
Model CT36G
215*
450
215*
600
600
215*
600
600
215*
500
150*
350
215*
600
600
500
CTWH30
CTWH36
IH4227
DD30
DD36
DD45
Pro Hoods
Modules
Model CT15I
Model IG15
Model IS15
Model IF15
Model IM15
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
150*
215*
215*
215*
215*
215*
215*
150*
*Use these requirements to determine total CFM when installing multiple cooktops or modules.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW).
Additional CFM may be required for long duct runs.
C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S
Downdraft Systems
Blower Description
500 CFM Internal
1100 CFM In-Line
900 CFM Remote
1200 CFM Remote
1500 CFM Remote
Blower Number
Downdraft Models
Included with (I) Models
BLOWER-110IL (808332)
BLOWER-90REM (801641)
BLOWER-120REM (801642)
BLOWER-150REM (804701)
DD30I / DD36I / DD45I
DD30R / DD36R / DD45R
DD30R / DD36R / DD45R
DD30R / DD36R / DD45R
DD30R / DD36R / DD45R
Adjustable discharge. 31/4" (83) x 10" (254) duct for internal blower, no transition required. 31/4" (83) x 14" (254) duct for in-line and
remote blowers. TRANS-14-10 required for remote blowers.
Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking product.
Always consult a qualified HVAC Engineer for specific applications.
Dimensions in parentheses are in
millimeters unless otherwise specified.
9
|