Samsung Aw07p2 User Manual

USER'S MANUAL  
AW07P2 Series  
AW09P2 Series  
AW12P2 Series  
Window-type Room Air Conditioner (Cooling)  
E
DB98-ꢀ7ꢀ04A  
DB98-27204A.indd  
15  
2007-1-23  
9:18:46  
Contents  
PREPARING YOUR AIR CONDITIONER  
n
Safety Precautions ........................................................................................  
4
n
Air Conditioning Unit-Main Parts and Control Panel.....................................  
OPERATION YOUR AIR CONDITIONER  
n
Cooling Your Room.......................................................................................  
5
n
n
n
n
n
Airing Your Room..........................................................................................  
Switching the Air Conditioner Off..................................................................  
Setting the Off Timer.....................................................................................  
Adjusting the Air Flow Direction Horizontally ................................................  
Adjusting the Air Flow Direction Vertically ....................................................  
6
6
7
7
8
RECOMMENDATIONS FOR USE  
n
Temperature and Humidity Ranges ..............................................................  
8
9
n
n
Cleaning Your Air Conditioner.......................................................................  
Solving Common Problems........................................................................... ꢁ0  
INSTALLATION............................................................................................. ꢁꢁ  
The illustrations in the step-by-step procedures use four different symbols:  
   
PRESS  
PUSH  
IMPORTANT  
NOTE  
CAUTION  
“The high inrush current of the starting compressor motor can have adverse effects to  
the operation of other equipment under unfavorable mains conditions. This equipment  
does not comply with the relevant technical standards for the limitation of voltage  
fluctuations and flicker.”  
Before connection this equipment to the power supply system, please report to your  
suply authority and obtain the consent.  
Do not connect other electric appliances to the same supply lines.  
E-3  
DB98-27204A.indd  
3
2007-1-23  
9:18:37  
Air Conditioning Unit - Main Parts and Control Panel  
The design and shape are subject to  
change according to the model.  
Air Outlet  
Inner air flow blades  
(right/left orientation)  
Air inlet (Inside)  
Outer air flow blades  
(up/down orientation)  
The air filter is  
located in side  
Air inlet (Outside)  
Ventilation lever  
Power Cable  
The type of the power plug  
may differ according to the  
type of local power supply.  
Power plug  
Operating mode  
selection dial  
Temperature  
control dial  
Air flow blade  
swing switch  
Fan speed switch  
E-4  
DB98-27204A.indd  
4
2007-1-23  
9:18:37  
Cooling Your Room  
You must select the Cool mode if you wish to lower the temperature  
in your room.You can also set the fan speed.  
To switch the unit on,simply turn the Timer dial to "Continue" position.  
The air conditioner starts operating.  
Result:  
To adjust the temperature, turn the temperature control dial  
to the desired position.  
Possible temperatures: Between ꢁ8 °C and ꢀ9 °C inclusive.  
Result:  
The air conditioner starts cooling if the room temperature is  
higher than the selected temperature.  
3
Press the "Fan Speed" mode selector to the High or Low position.  
Result:  
The Fan speed is adjusted.  
E-5  
DB98-27204A.indd  
5
2007-1-23  
9:18:37  
Airing Your Room  
If the atmosphere in your room is stale, you can air it using the Fan  
feature and if necessary, evacuate the stale air outside.  
If you wish to evacuate stale air outside, push the ventilation lever on the  
front of the unit to the right and the open position ( ).  
Result:  
Otherwise, push the ventilation lever to the left and the closed position (  
Result: The air simply circulates inside the room.  
The air inside the room circulates and stale air is evacuated outside.  
).  
To switch the unit on,simply turn the Timer dial to "Continue" position.  
Result:  
The air conditioner starts operating.  
3
To airing your room only, turn the temperature control dial  
to "ꢁ" position.  
The air conditioner runs in fan mode.  
Result:  
Press the "Fan Speed" mode selector to the High or Low position.  
The Fan speed is adjusted.  
4
Result:  
Switching the Air Conditioner Off  
You can switch the air conditioner off whenever you want.  
To switch the unit off, simply turn the Timer dial to the "off " position.  
Result: The air conditioner stops operating.  
E-6  
DB98-27204A.indd  
6
2007-1-23  
9:18:38  
Setting the Off Timer  
The Off Timer enables you to switch off the air conditioner automatically  
after a given period of time. You can set the period of time from 0 hour  
to12 hours.  
You can set the Off Time at any time.  
To set the off time, simply turn the Timer dial to the time you want.  
Possible time is lower ꢁꢀ hours inclusive.  
To cancel the Off Timer function,That is to say,make the unit run  
incessantly, you can turn the timer dial to "Continue" position.  
Result:  
The air conditioner switches off automatically when the  
operating time reaches zero  
Adjusting the Air Flow Direction Horizontally  
Depending on the position of the unit in your room, you can adjust the  
orientation of the inner air flow blades on the right-hand side of the unit,  
thus increasing the efficiency of the air conditioner.  
Set the air flow blade swing switch to the on position.  
Result: The inner blades swing automatically left and right.  
To stop the blades moving left and right, set the air flow blade swing  
switch to the off position.  
To stop the blades in a specific position and orient the air flow in  
the corresponding direction, simply set the switch to the off  
position when the blades are in the desired position.  
E-7  
DB98-27204A.indd  
7
2007-1-23  
9:18:39  
Adjusting the Air Flow Direction Vertically  
Again depending on the position of the unit in your room, you can adjust  
the orientation of the outer air flow blades on the right-hand side of the unit.  
RECOMMENDATION  
When...  
Adjust the blades to face...  
Cooling  
Upwards.  
Adjust the air flow blades to the desired position, by pushing them upwards or  
downwards.  
If you orient the air flow blades downwards and the unit operates in Cool mode  
for long periods of time, dew may:  
From on the surface of the blades  
Drip from the blades  
Temperature and Humidity Ranges  
The following table indicates the temperature and humidity ranges  
within which the air conditioner can be used in the best condition .  
Mode  
IndoorTemperature  
OutdoorTemperature  
Indoor Humidity  
Cooling  
ꢀꢁ°C to 3ꢀ°C approx.  
ꢀꢁ°C to 43°C approx.  
80% or less  
If the air conditioner is used at...  
Then...  
The automatic protection feature may be triggered and the air  
conditioner stopped.  
Higher temperatures  
A water leakage or some other malfunction may happen if the  
heat exchanger freezes.  
Lower temperatures  
Water way condense on and drip from the surface of the unit if  
it is used for long periods.  
Higher humidity levels  
E-8  
DB98-27204A.indd  
8
2007-1-23  
9:18:39  
Cleaning Your Air Conditioner  
Be sure to clean the air filter periodically to maintain the air conditioner in  
the best condition for a long period of time.  
When cleaning the air conditioner, turn it off and pull out  
the power plug.  
IMPORTANT  
Hold the front grille handle, slightly pull it to the left side and open the front grille.  
The removal of the front grille makes it easier to clean the air  
conditioner. Open the grille as much as possible.  
CAUTION  
Removal and Reassembly of the Front Grille  
Grasp the lower part of the front  
grille and the front grille handle,  
then open the grille. (The open  
angle of front grille has not to be  
exceeded ꢀ5 degree)  
3
Lift the front grille slightly and  
remove it from the front panel.  
Reassembling of front grille  
should be done in reverse  
order of disassembly.  
3
4
5
Pull the air filter to the right side.  
Remove all dust on the air filter with a vacuum cleaner or brush.  
When you have finished, insert the air filter back into its original position.  
Wipe the surface of the unit with a neutral detergent and then wipe it again  
with dry cloth.  
(Be sure not to use benzene, solvent or other chemical products.)  
If you...  
Then...  
The air conditioner has two or three grille  
grooves depending on the model.  
Will not be using the  
air conditioner for a  
long period of time  
Set the operating mode selection dial  
to “LOW FAN” and let it run of a few  
hours to dry the inside of the air  
conditioner thoroughly.  
Switch the air conditioner off and  
unplug it from the wall socket.  
Clean the filter and outer surfaces.  
Have not used the air  
conditioner for a long  
period of time  
Set the operating mode selection dial  
to “LOW FAN” and let it run of a few  
hours to dry the inside of the air  
conditioner thoroughly.  
E-9  
DB98-27204A.indd  
9
2007-1-23  
9:18:42  
Solving Common Problems  
Before contacting the after-sales service,perform the following simple checks.  
They may save you the time and expense of an unnecessary service call.  
Problem  
Explanation/Solution  
The air conditioner does not  
operate at all  
Check that the circuit breaker used for the air conditioner has not  
been triggered.  
Check that the power cable is plugged into a wall socket and the  
socket is switched on, if necessary.  
Check that the correct operating mode has been selected  
(cooling or airing).  
The air conditioner does not cool  
Check that the correct operating mode has been selected .  
The room temperature may be too low.  
Dust may be blocking the air filter; refer to page 8  
cleaning instructions.  
Check that there is no obstacle blocking the air flow into or out of  
the unit.  
The air flow direction does not  
change when you set the air  
flow blade swing switch to the  
on position  
Check that the air conditioner has been switched on;  
if necessary, turn the operating mode selection dial;  
refer to page 7.  
Odours are permeated in the  
room during air conditioning  
Air the room.  
E-ꢁ0  
DB98-27204A.indd  
10  
2007-1-23  
9:18:43  
Installation  
Before installation, be sure to check the installation area or the air  
conditioner, and drain hose.  
Checkpoints prior to installation  
Check the cabinet and front grille of the unit for any harmful defects  
such as scratches.  
Be sure to check the power supply.  
- Refer to the specifications on the label attached to the unit.  
Installation Conditions  
As the unit is heavy, the wall or window of the installation area should  
have sufficient strength and durability for operation of the air conditioner,  
and for prevention of any vibration or noise.  
If it is weak, reinforcement work should be performed separately.  
It is advisable to install the air conditioner in the north or west side to  
prevent the effect of direct sunlight.  
When installing it in the south or east side due to unavoidable  
circumstances, it is advisable to install the sunshade to prevent the  
direct sunlight.  
In this case, take care not to cause any hindrance to the flow of outside air.  
3
When installing the air conditioner, be sure to obtain sufficient space on  
the rear side of the unit for smooth flow of air.  
When operating the air conditioner in closed areas such as inner building  
with cooling operation, and result in trouble with the unit.  
See the illustration below.  
Awning  
The appliance must be fixed well by screw or similar  
method.  
75mm  
min.  
300mm  
"A"  
Fence, wall  
or other  
500mm  
500mm  
500mm  
obstacle  
Approx.3  
MODEL  
AW07/AW09  
AWꢁꢀ  
“A”  
ꢁ45  
ꢁ70  
750mm  
150mm min.  
If the wall is greater than ꢁ50mm thick,  
cut the wall back on a 45° angle if possible.  
Outdoor side  
Indoor side  
45  
45  
ꢁ00mm or more  
E-ꢁꢁ  
DB98-27204A.indd  
11  
2007-1-23  
9:18:44  
Installation(Cont.)  
Installation of the Drain Tube  
Fix the drain tube as shown in the figure.  
Rear  
Rubber cap  
Gasket  
Drain Tube  
Screws(ꢀEA)  
E-ꢁꢀ  
DB98-27204A.indd  
12  
2007-1-23  
9:18:44  
Memo  
E-ꢁ3  
DB98-27204A.indd  
13  
2007-1-23  
9:18:44  
DB98-27204A.indd  
14  
2007-1-23  
9:18:45  

Lanier 5505 User Manual
Ricoh Aficio Mp C2030 User Manual
Ryobi Ch120l User Manual
Samsung Aw12f2dbb User Manual
Samsung Aw0693l User Manual
Schumacher Ps 1022ma User Manual
Source Technologies Ac048x1222a User Manual
Whirlpool 4380701 User Manual
Whirlpool Acd052pk0 User Manual
Xerox Pasher 6125 User Manual